OMRON G6K /

OMRON G6K specifications

G6K-2G DC24

OMRON G6K-2G DC24 is listed in the manufacturer ordering table with a 24 VDC coil, DPDT (2c) contacts, single-side stable operation and inside-L surface mount terminals. Review the load and PCB requirements before ordering.

Manufacturer source reviewed Request this exact model
01 / EXACT IDENTITY

G6K-2G DC24 specifications

Use these specifications to identify your BOM line. MZZ confirms availability, quantity and delivery against your purchasing requirement.

Nominal coil
24 VDC
Contact arrangement
DPDT (2c)
Relay function
single-side stable
Terminals
inside-L surface mount
Enclosure
fully sealed
Coil resistance
5220 ohm; 23 C coil temperature; rated current and resistance tolerance +/-10%
Rated coil current
4.6 mA at rated coil voltage; 23 C coil temperature; rated current and resistance tolerance +/-10%
Resistive contact rating
0.3 A at 125 VAC; 1 A at 30 VDC
Maximum switching current
1 A; apply the manufacturer's voltage/load curve
Rated carry current
2 A; carrying current is not the switching rating
Operating ambient
-40 to 85 C; no icing or condensation
Body height
5.4 mm nominal; check the original drawing and land pattern

Related packing order codes

These manufacturer-listed order codes share the reviewed electrical model and coil voltage. Packaging differs; keep your requested code in the BOM and confirm the required packing before purchase.

02 / DIFFERENCE CONTROL

Why the complete code matters

G6K-2G identifies the single-side stable inside-L surface mount version; DC24 fixes the rated coil voltage. Preserve Y, T1, RF and packaging suffixes where specified. Confirm polarity/drive timing for latching versions and use the exact PCB drawing. Rated carry current must not be substituted for switching capability.

03 / APPLICATION SCREENING

Where the G6K family may fit

These are family-level screening examples. Final suitability depends on the exact load, environment, required life and approvals.

  • Measurement and instrumentation signal paths after exact load and contact-life review
  • Communication and equipment control circuits with verified PCB footprint and drive requirements
  • Compact control boards where coil power, switching function and packing format matter
04 / RFQ CHECKS

What MZZ verifies before quoting

The original BOM code remains unchanged while commercial and technical conditions are checked.

  • Full manufacturer ordering code and every suffix
  • Coil voltage, polarity and switching or latching drive
  • Contact arrangement, switching load and electrical-life requirement
  • PCB terminals, land pattern, enclosure and packing format
  • Required quantity, destination, target date and documentation
05 / PRIMARY EVIDENCE

Manufacturer source

The linked manufacturer record controls technical selection. MZZ rechecks the current source and actual supply conditions after receiving the required quantity and destination.

Need G6K-2G DC24 or another G6K variant?

Send the exact MPN, quantity, destination and required date.

Open the RFQ form